TRIPP LITE Part #/MPN: AVRT650U
DiscTech Item #: TRI-AVRT650U-BN-3Y
- Brand New
- Warranty:3 Year Manufacturer
- Special Order - Ships in 3-5 business days
Interface Types: IEC 5-15P
Bays/Ports/Slots: 6
U Height: 2U
Wattage/VA: 480W
Voltage: 110-120V
Tripp Lite AVR Series AVRT650U 120V 650VA 480W Line-Interactive UPS Tower Battery Backup - Brand New
Tripp Lite AVR Series AVRT650U 120V / 120 Volt 650VA / 650 Volt-Amps 480W / 480 Watts Line-Interactive UPS / Uninterruptible Power Supply Tower Battery Backup with 6 USB Ports (4 UPS battery backup outlets and 2 additional surge-only outlets) - Brand New
650VA 480W Line-Interactive UPS with 6 Outlets - AVR, 120V, 50/60 Hz, USB, Tower
Line-interactive UPS provides basic battery backup with automatic voltage regulation for your office computer or home theater setup.
- Protects equipment against blackouts, brownouts, overvoltages, surges and line noise
- AVR battery backup allows time to save files and safely shut down during blackouts
- 6 NEMA 5-15R outlets provide power to PC, home theater or digital signage equipment
- Easy-to-see LEDs indicate operating mode, low battery, overload and other vital data
- High >95% efficiency with low BTU ratings saves power and lowers your energy costs
- 3-year limited warranty
- $100,000 Ultimate Lifetime Insurance
Features
650VA/480W/120V Battery Backup for PCs, Home Theater or Digital Signage
This 120V UPS with AVR protection provides reliable battery backup and AC power protection against blackouts, brownouts, overvoltages, surges and line noise that can damage valuable electronics or destroy data. The six-outlet 120V battery backup is ideal protection for your home office, media center or commerce components, including computers, routers, printers, HDTVs, Blu-ray players, game consoles, ATMs, security systems and digital signage equipment.
Allows Time to Back Up Critical Files During a Blackout
Backup support allows you to work through short power failures, and gives you enough time to safely save files and shut down your system in case of a prolonged blackout. Backup time varies according to load, but the line-interactive UPS system should keep an energy-efficient desktop computer with small LCD monitor powered as long as 45 minutes. During normal operation, incoming utility power keeps the replaceable internal battery fully charged, so backup power will always be available.
Connects Your Equipment to 6 NEMA 5-15R Outlets
Four 5-15R outlets provide both battery backup and surge protection for your computer, monitor and other crucial components. The other two 5-15R outlets are surge-protected only for printers, scanners and other non-essential equipment. A high >95% line mode efficiency rating reduces BTU emissions, energy consumption and, ultimately, your energy costs.
Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions
AVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts and overvoltages. The AVRT650U can correct brownouts as low as 89V and overvoltages as high as 145V back to nominal 120V power without drawing on the battery backup needed to support your equipment during a blackout.
316 Joules Fight Back Against Unexpected Power Surges
A 316-joule surge suppression rating protects connected components from the harmful effects of power surges.
Combats Electromagnetic Interference That Can Harm Equipment
Various electromagnetic and radio sources found in virtually every home and business can cause disruptive interference on the AC line. Known as EMI (electromagnetic interference) and RFI (radio frequency interference), this line noise is a common cause of performance problems and can lead to incremental hardware damage, data corruption and audio/video transmission problems. The AVRT650U incorporates technology that filters out disruptive line noise so that it won’t affect your equipment.
Easy-to-See LEDs Report Real Time UPS and Power Status
Front-panel LEDs provide UPS and site power information when the AVRT650U is operating in either on-line or battery power mode. They indicate operating mode, low battery, overload and fault condition. An audible alarm will sound in case of low battery, excessive load and fault condition.
HID-Compliant USB Port Allows for Automatic Saves and Shutdowns
This port connects the AVRT650U to a computer running Tripp Lite’s free downloadable PowerAlert® software to enable safe unattended file saves and system shutdown in case of a prolonged power failure. USB cable is included. The UPS works with Windows, Mac and Linux operating systems.
Tower Form Factor for Easy Placement in Your Workspace or Media Center
The long-lasting ABS housing fits easily on a desktop, shelf or anywhere else convenient to your workstation or home theater. The five-foot power cord with NEMA 5-15P plug connects to a properly grounded AC wall outlet.
Applications
- Protect your PC and other sensitive electronics against power surges, line noise, brownouts, overvoltages and blackouts
- Operate essential equipment during short-term power outages using battery backup power
- Shut down PCs, DVRs, routers and other equipment without data loss during long-term power outages
Package Includes
- AVRT650U 650VA 480W LineInteractive UPS with 6 Outlets
- USB cable
- Owner’s manual
TRIPP LITE UPS BATTERY BACKUP | |
---|---|
Model Number | AVRT650U |
OVERVIEW | |
UPS Type | Line-Interactive |
OUTPUT | |
Output Volt Amp Capacity (VA) | 650 |
Output Watt Capacity (Watts) | 480 |
Power Factor The ratio of active power (watts) to apparent power (VA). Most computer-related equipment has a power factor between 0.6 and 0.8. Power factor is the spread between VA and wattage. For example, VA x power factor = watts. | 0.74 |
Nominal Voltage Details | 120v nominal output in battery mode |
Frequency Compatibility | 50 / 60 Hz |
Frequency Compatibility Details | Automatic frequency selection |
Output Voltage Regulation (Line Mode) | 120V (+9% / -12%) |
Output Voltage Regulation (Battery Mode) | 120V (±10%) |
UPS Output Receptacles (Surge Suppression Only) | 4 UPS outlets, 2 surge-only outlets |
Hot-Swap PDU options | PDUB15 (2U / 8 5-15R outlets) |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | PWM sine wave |
Nominal Output Voltage(s) Supported | |
Output Receptacles | (6) 5-15R |
Individually Controllable Load Banks Select UPS models have their receptacles divided into one or more load banks (labeled LOAD 1, ect.) which may be remotely switched OFF and ON using Tripp Lite UPS software without interrupting power to equipment connected to the other outlets | No |
INPUT | |
Rated input current (Maximum Load) | 6A |
Nominal Input Voltage(s) Supported | |
UPS Input Connection Type | 5-15P |
Input Circuit Breakers | 7A |
UPS Input Cord Length (ft.) | 5 |
Recommended Electrical Service | 15A 120V |
Input Phase | Single-Phase |
BATTERY | |
Half Load Runtime (min.) The amount of runtime th UPS will offer when you | 3.8 minutes (240w) |
DC System Voltage (VDC) | 12 |
Battery Recharge Rate (Included Batteries) | 8 hours from 10% to 90% |
Internal UPS Replacement Battery Cartridge | RBC51 |
Battery Access | Includes bottom panel battery access door |
Battery Replacement Description | Replaceable internal battery (see manual) |
Expandable Runtime | No |
VOLTAGE REGULATION | |
Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 89 to 145 |
Overvoltage Correction A feature found in line conditioners and select UPS systems that maintains mains-level power to equipment when prolonged line voltages are higher than normal | Input voltages between 129 and 145 are reduced by 15% |
Undervoltage Correction A feature found in line conditioners and select UPS systems that maintains main-level power to equipment when prolonged line voltages are lower than normal | Input voltages between 89 and 108 are boosted by 14% |
USER INTERFACE, ALERTS & CONTROLS | |
Switches | Power switch enables UPS on / off control |
Audible Alarm | |
LED Indicators | 3 LEDs indicate |
SURGE / NOISE SUPPRESSION | |
UPS AC Suppression Joule Rating | 316 |
UPS AC Suppression Response Time | Instantaneous |
UPS Dataline Suppression | N/A |
EMI / RFI AC Noise Suppression Technology found in select UPS systems that protects against EMI (electromagnetic interference) and RFI (radio frequency interference) line noise and protects equipment against associated incremental hardware damage, data corruption and audio/video transmission problems. | Yes |
PHYSICAL | |
Installation Form Factors Supported with Included Accessories | Tower |
Primary Form Factor | Tower |
Primary UPS Depth (mm) | 345 |
Primary UPS Height (mm) | 160 |
Primary UPS Width (mm) | 122 |
Shipping Dimensions (hwd / in.) | 9.80 x 7.20 x 16.30 |
UPS Housing Material | ABS |
UPS Power Module Dimensions (hwd, in.) | 6.3 x 4.8 x 13.6 |
UPS Power Module Weight (kg) | 5.49 |
UPS Power Module Weight (lbs.) | 12.1 |
ENVIRONMENTAL | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius. |
Storage Temperature Range | +5 to +113 degrees Fahrenheit / -15 to +45 degrees Celsius. |
Relative Humidity | Up to 90%, non-condensing |
AC Mode BTU / Hr. (Full Load) The amount of heat a UPS generates when operating under a full load on mains (AC) power. Measured in British Thermal Units (BTU). | 41 |
AC Mode Efficiency Rating (100% Load) | >95% |
Operating Elevation (ft.) | Operating Elevation (ft.) |
Operating Elevation (m) | Up to 3000 m |
COMMUNICATIONS | |
Communications Interface | USB (HID enabled) |
PowerAlert Software | For local monitoring via the UPS’s built-in USB communications port, download PowerAlert Local software at http://www.tripplite.com/poweralert |
Communications Cable | USB interface cable included |
WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
Network UPS Tools Compatibility | |
LINE / BATTERY TRANSFER | |
Transfer Time The time it takes for a UPS to switch from AC on-line mode to DC battery-powered mode. Measured in milliseconds (ms) | 6 milliseconds |
Low Voltage Transfer to Battery Power (Setpoint) | 89 |
High Voltage Transfer to Battery Power (Setpoint) | 145 |
SPECIAL FEATURES | |
Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
High Availability UPS Features | Battery Independent Restart |
Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS |
CERTIFICATIONS | |
UPS Certifications | |
UPS Certification Details | UL1778: |
WARRANTY | |
Product Warranty Period (U.S. & Canada) | 3-year limited warranty |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $100,000 Ultimate Lifetime Insurance |
Click here to view the manufacturer's item description/brochure
ROHS Compliant
Weight: 13 lb
Warranty: 3 Year Manufacturer
Brand New
3 Year Manufacturer Warranty