Tripp Lite OMNI1500LCDT 1500VA Line Interactive UPS Tower Battery Backup

TRIPP LITE Part #/MPN: OMNI1500LCDT

DiscTech Item #: TRI-OMNI1500LCDT-BN-3Y


$229.00
  • Low Stock:Call for ETA
    Stock Levels

    This item is currently (nearly) out of stock. It may be possible to arrange fast shipment. If you need it urgently call us. Otherwise, it usually ships within 1 week.

$229.00

Interface Types: IEC 5-15P

Bays/Ports/Slots: 10

U Height: 2U

Wattage/VA: 810W

Voltage: 110-120V

Tripp Lite OmniSmart OMNI1500LCDT 120V 1500VA 810W Line-Interactive UPS Tower Battery Backup w/ LCD, USB Port & ENERGY STAR V20 - Brand New

Tripp Lite OmniSmart OMNI1500LCDT 120V / 120 Volts 1500VA 1500 Volt-Amps 810W / 810 Watts Line-Interactive Energy Star V2.0 Uninterruptible Power Supply Tower Battery Backup with 10 USB Ports (5 UPS Battery Backup Outlets and 5 Additional Surge-Only Outlets) and LCD / Liquid Crystal Display Touchscrean & HID / human interface device Compliant USB / Universal Serial Bus Port - Brand New

OmniSmart LCD 120V 50/60Hz 1500VA 810W Line-Interactive UPS, Tower, LCD display, USB port, Energy Star V2.0

Description
Tripp Lite's OMNI1500LCDT Line-Interactive Tower UPS System offers voltage regulation, surge suppression and long-lasting battery support for personal computers, network workstations, home entertainment systems and media centers. Internal UPS circuits support entry-level PCs or individual VCR/DVR components during power failures. Prevents data loss, viewing interruptions, lost recordings and loss of component programming. Automatic Voltage Regulation (AVR) circuits continuously regulate brownouts and overvoltages from 92V to 150V back to usable levels, all while maintaining a full battery charge. Offers complete power protection in an attractive all-black cabinet design. Includes 10 built-in outlets, 5 with full battery backup and surge suppression for vital system components and another 5 with surge-suppression only for accessories not requiring battery support. Built-in USB port and included cable enables optional unattended system shutdown without data loss in case of extended power failure. PowerAlert software is available via free download. HID-compliant USB interface also enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Built-in surge dataline surge suppression jacks protect equipment with single-line dialup/DSL or network Ethernet connection. Built-in audible alarm and large LCD front panel display offers easy to read icon-based status indicators and detailed numeric data regarding input voltage, output voltage, frequency, load percentage, load watts, battery voltage and runtime in minutes. 1500VA/810W power-handling capacity supports entry-level PCs, home entertainment systems, network workstations and audio/video components.

Features

  • OMNI1500LCDT line interactive UPS offers network-grade voltage regulation, surge suppression and long lasting battery support
  • 10 built-in NEMA 5-15R outlets, 5 with UPS and surge suppression for vital components and 5 additional outlets with surge-only protection for devices not requiring battery support
  • NEMA 5-15P input plug; 6ft / 1.8m line cord
  • Maintains operation of connected equipment to prevent data loss, equipment damage and downtime associated with power failures and severe voltage fluctuations
  • Line Interactive Automatic Voltage Regulation / AVR circuits continuously correct brownouts and overvoltages from 92 to 150V without using battery power
  • Network-grade AC surge suppression protects equipment from damage and performance problems resulting from transient surges
  • Offers 7.5 minutes runtime 50% load (405 watts)
  • Supports an entry level desktop system with LCD screen for up to 55 minutes during power failures (75 watts)
  • LCD display continuously reports operating mode and battery charge level, plus additional UPS and site power data, such as input & output voltage, frequency, load percentage, load watts, battery voltage and estimated runtime in minutes
  • USB port enables data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from Tripp Lite PowerAlert Platform
  • HID-compliant USB interface also enables automatic integration with built-in power management and auto shutdown features of Windows and Mac OSX
  • Built-in data line surge suppression offers protection for equipment with single-line dialup or network ethernet connection, plus one set of coax jacks for CATV / broadcast line protection
  • Meets strict ENERGY STAR Version 2.0 efficiency guidelines Optional PDUB15 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment

Highlights

  • 1500VA / 1.5kVA tower 120V line interactive UPS with LCD display
  • Maintains battery derived AC output during power failures
  • Corrects brownouts and overvoltages from 92-150V
  • LCD interface offers detailed UPS status and site power information
  • USB interface, TEL/DSL/ethernet and coax line surge suppression
  • NEMA 5-15P input plug and 10 NEMA 5-15R outlets
  • ENERGY STAR Version 2.0 qualified

Package Includes

  • OMNI1500LCDT UPS
  • USB cabling
  • Manual with warranty information

TRIPP LITE LINE-INTERACTIVE UPS BATTERY BACKUP
Model NumberOMNI1500LCDT
OVERVIEW
UPS TypeLine-Interactive
OUTPUT
Output Volt Amp Capacity (VA)1500
Output kVA Capacity (kVA)1.5
Output Watt Capacity (Watts)810
Power Factor

The ratio of active power (watts) to apparent power (VA). Most computer-related equipment has a power factor between 0.6 and 0.8. Power factor is the spread between VA and wattage. For example, VA x power factor = watts
0.7
Nominal Voltage Details120v nominal output in battery mode
Frequency Compatibility50 / 60 Hz
Frequency Compatibility DetailsAutomatic frequency selection
Output Voltage Regulation (Line Mode)120V (+9% / -12%)
Output Voltage Regulation (Economy Line Mode)120V (±10%)
Output Voltage Regulation (Battery Mode)+/- 5%
UPS Output Receptacles (Surge Suppression Only)
  • 5 UPS outlets
  • 5 surge-only outlets
  • Hot-Swap PDU optionsPDUB15 (2U / 8 5-15R outlets)
    Output AC Waveform (AC Mode)Sine wave
    Output AC Waveform (Battery Mode)PWM sine wave
    Nominal Output Voltage(s) Supported
  • 110V
  • 115V
  • 120V
  • Output Receptacles(10) 5-15R
    Individually Controllable Load Banks

    Select UPS models have their receptacles divided into one or more load banks (labeled LOAD 1, ect.) which may be remotely switched OFF and ON using Tripp Lite UPS software without interrupting power to equipment connected to the other outlets
    No
    INPUT
    Rated input current (Maximum Load)12A
    Nominal Input Voltage(s) Supported120V AC
    UPS Input Connection Type5-15P
    Input Circuit Breakers15A
    UPS Input Cord Length (ft.)6
    Recommended Electrical Service15A 120V
    Input PhaseSingle-Phase
    BATTERY
    Half Load Runtime (min.)

    The amount of runtime th UPS will offer when you
    7.5 minutes (405 watts)
    DC System Voltage (VDC)24
    Battery Recharge Rate (Included Batteries)Less than 8 hours from 10% to 90%
    Internal UPS Replacement Battery CartridgeQty 2 RBC51
    Expandable RuntimeNo
    VOLTAGE REGULATION
    Voltage Regulation DescriptionAutomatic voltage regulation (AVR) maintains line power operation with an input voltage range of 92 to 150
    Overvoltage Correction

    A feature found in line conditioners and select UPS systems that maintains mains-level power to equipment when prolonged line voltages are lower than normal
    Input voltages between 129 and 147 are reduced by 15%
    Undervoltage Correction

    A feature found in line conditioners and select UPS systems that maintains mains-level power to equipment when prolonged line voltages are lower than normal
    Input voltages between 92 and 108 are boosted by 18%
    USER INTERFACE, ALERTS & CONTROLS
    Front Panel LCD Display
  • LCD screen with scroll buttons indicates Input voltage
  • Output voltage
  • Frequency (Hz)
  • AVR boost / cut status
  • Output load in watts
  • Output load percentage
  • Battery voltage and Estimated runtime in minutes
  • Switches
  • Power switch offers whole UPS power control
  • Scroll/mute button enables LCD selection options and silences audible alarm
  • Test button initiates self test
  • Alarm Cancel OperationPower-fail alarm can be silenced using alarm-cancel switch
    Audible AlarmAudible alarm indicates power-failure and low-battery conditions
    SURGE / NOISE SUPPRESSION
    UPS AC Suppression Joule Rating650
    UPS AC Suppression Response TimeInstantaneous
    UPS Dataline Suppression
  • 1 line TEL/DSL (1 in / 1 out)
  • 10/100Base T Ethernet
  • Coax jacks (1 set)
  • EMI / RFI AC Noise Suppression

    Technology found in select UPS systems that protects against EMI (electromagnetic interference) and RFI (radio frequency interference) line noise and protects equipment against associated incremental hardware damage, data corruption and audio/video transmission problems.
    Yes
    PHYSICAL
    Cooling MethodFan
    Installation Form Factors Supported with Included AccessoriesTower
    Primary Form FactorTower
    Primary UPS Depth (mm)396
    Primary UPS Height (mm)203
    Primary UPS Width (mm)146
    Shipping Dimensions (hwd / in.)11.20 x 9.10 x 19.40
    Shipping Weight (lbs.)25.20
    UPS Power Module Dimensions (hwd, in.)8 x 5.75 x 15.6
    UPS Power Module Weight (kg)11.52
    UPS Power Module Weight (lbs.)25.4
    ENVIRONMENTAL
    Operating Temperature Range+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
    Storage Temperature Range+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
    Relative HumidityUp to 95%, non-condensing
    AC Mode BTU / Hr. (Full Load)

    The amount of heat a UPS generates when operating under a full load on mains (AC) power. Measured in British Thernal Units(BTUs)
    98
    Battery Mode BTU / Hr (Full Load)

    The amount of heat a UPS generates when operating under a full load on battery (DC) power. Measured in British Thernal Units(BTUs)
    826
    AC Mode Efficiency Rating (100% Load)>95%
    COMMUNICATIONS
    Communications InterfaceUSB (HID enabled)
    PowerAlert SoftwareFor local monitoring via the UPS’s built-in USB communications port, download PowerAlert Local software at http://www.tripplite.com/poweralert
    Communications CableUSB interface cable included
    WatchDog CompatibilitySupports Watchdog application, OS and hard-reboot restart options for remote applications
    Network UPS Tools CompatibilityNUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at Network UPS Tools
    LINE / BATTERY TRANSFER
    Transfer Time

    The time it takes for a UPS to switch from AC on-line mode to DC battery-powered mode. Measured in milliseconds (ms)
  • 2 milliseconds (AC to battery mode)
  • 6 milliseconds (battery to AC mode)
  • Low Voltage Transfer to Battery Power (Setpoint)92
    High Voltage Transfer to Battery Power (Setpoint)150
    SPECIAL FEATURES
    Cold Start (Startup in Battery Mode During a Power Failure)Cold-start operation supported
    High Availability UPS FeaturesHot Swappable Batteries
    Green Energy-Saving FeaturesGreater than 95% efficiency - GREEN UPS
    CERTIFICATIONS
    UPS Certifications
  • ENERGY STAR Qualified
  • Meets FCC Part 15 Category B (EMI)
  • Tested to CSA (Canada)
  • Tested to NOM (Mexico)
  • Tested to UL1778 (USA)
  • UPS Certification DetailsENERGY STAR Version 2.0 Qualified
    WARRANTY
    Product Warranty Period (U.S. & Canada)3-year limited warranty
    Connected Equipment Insurance (U.S., Canada & Puerto Rico)$250,000 Ultimate Lifetime Insurance

    Click here to view the manufacturer's item description/brochure

    Weight: 26.5 lb

    Warranty: 3 Year Manufacturer

    Brand New

    Condition Levels Explained

    The product is brand new.

    3 Year Manufacturer Warranty

    Product Warranties Explained

    The product has a manufacturer warranty for the time period specified.