Tripp Lite OMNI750ISO 750VA Line-Interactive UPS Tower Battery Backup

- Brand NewCondition Levels Explained
The product is brand new.
- Low Stock:Call for ETAStock Levels
This item is currently (nearly) out of stock. It may be possible to arrange fast shipment. If you need it urgently call us. Otherwise, it usually ships within 1 week.
- 2 Year ManufacturerWarrantyProduct Warranties Explained
The product has a manufacturer warranty for the time period specified.
Interface Types: | IEC 5-15P |
Bays/Ports/Slots: | 6 |
U Height: | 2U |
Voltage: | 110-120V |
Description
Tripp Lite OmniSmart OMNI750ISO 120V 750VA 500W Line-Interactive UPS Tower Battery Backup w/ Built-In Isolation Transformer & USB port - Brand New
Tripp Lite OmniSmart OMNI750ISO 120V / 120 Volt 750VA / 750 Volt-Amps 500W / 500 Watts Line-Interactive UPS / Uninterruptible Power Supply Tower Battery Backup with 6 UPS-supported AC outlets and w/ Built-In Isolation Transformer with Faraday shield & USB communications port - Brand New
OmniSmart 120V 750VA 500W Line-Interactive UPS, Tower, Built-In Isolation Transformer, USB port
Description
Tripp Lite's OMNI750ISO offers complete UPS protection with built-in line-interactive voltage regulation, intelligent monitoring and unattended shutdown capability. Built-in isolation transformer with Faraday shield offers full isolation and complete common mode noise rejection. 750VA power-handling capacity supports point-of-sale applications, computers, internetworking equipment and home theater systems during commercial power failures. Line-interactive voltage regulation corrects brownouts as low as 81V and overvoltages as high as 143V back to normal 120V levels, saving battery power for use during complete power failures. Built-in USB communications port works with PowerAlert Software and cabling to provide automatic unattended shutdown of connected network and PC applications.
Features
- 750VA line-interactive UPS with Faraday-shielded, low-impedance isolation transformer delivers full isolation from potential damage and performance problems
- Provides immunity from EMI/RFI line noise in both normal and common modes. Delivers clean signal reference ground, reducing data errors and audio/video distortion
- Automatic voltage regulation (AVR) automatically corrects incoming voltage to keep equipment working through low voltage (brownouts) as low as 81V and overvoltages as high as 143V without consuming battery power
- Supports loads up to 750VA/500W
- Offers 31.3 min. battery runtime with a half load of 375VA/250W and 13.5 min. with a full load of 750VA/500 watts
- Electrostatic discharge (ESD) resistance reduces potential static damage to connected electronics
- USB port enables data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert
- Built-in surge suppression (backed by $200,000 Ultimate Lifetime Insurance U.S., Canada, and Puerto Rico only) safeguards connected equipment against damage
- SURGE VOLTAGE WITHSTAND CAPABILITY: ANSI/IEEE C62.41 Catagories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave
- SURGE VOLTAGE ATTENUATION: N-G 2000:1, L-G 240:1, L-N 100:1
- INSERTION LOSS: 65 db N-G from 10Khz to 100Khz, 45 to 60 db L-G from 10Khz to 100Khz, 18 to 54 db L-N from 50Khz to 500 Khz
- 6 UPS-supported AC outlets; 6-ft. cord
- 5 diagnostic LEDs indicate AC present, on battery, voltage correction status, overload and battery low/replace
- Optional PDUB15 bypass PDU enables hot-swappable UPS replacement with no disruption to connected equipment
Highlights
- 750VA tower 120V line interactive UPS with isolation transformer
- Corrects brownouts and overvoltages from 81V to 143V
- USB port, Normal & common mode EMI/RFI line noise immunity
- NEMA 5-15P input plug and 6 5-15R outlets
Package Includes
- OMNI750ISO UPS system
- USB cable
- Instruction manual
Specifications
TRIPP LITE LINE-INTERACTIVE UPS BATTERY BACKUP | |
---|---|
Model Number | OMNI750ISO |
OVERVIEW | |
UPS Type | Line-Interactive |
OUTPUT | |
Output Volt Amp Capacity (VA) | 750 |
Output Watt Capacity (Watts) | 500 |
Nominal Voltage Details | 115v nominal output in battery mode |
Frequency Compatibility | 60 Hz |
Output Voltage Regulation (Line Mode) | |
Output Voltage Regulation (Battery Mode) | +/-5% |
Hot-Swap PDU options | PDUB15 (2U / 8 5-15R outlets) |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | PMW Sine wave |
Nominal Output Voltage(s) Supported | |
Output Receptacles | (6) 5-15R |
Individually Controllable Load Banks Select UPS models have their receptacles divided into one or more load banks (labeled LOAD 1, etc) which may be remotely switched OFF and ON using Tripp Lite UPS software without interrupting power to equipment connected to the other outlets | No |
INPUT | |
Rated input current (Maximum Load) | 5.5A |
Nominal Input Voltage(s) Supported | 120V AC |
UPS Input Connection Type | 5-15P |
UPS Input Cord Length (ft.) | 6 |
Recommended Electrical Service | 15A 120V |
Input Phase | Single-Phase |
BATTERY | |
Full Load Runtime (min.) The amount of runtime th UPS will offer when you | 13.5 min. (500w) |
Half Load Runtime (min.) The amount of runtime th UPS will offer when you | 31.3 min. (250w) |
DC System Voltage (VDC) | 36 |
Battery Recharge Rate (Included Batteries) | Less than 4.5 hours from 10% to 90% |
Internal UPS Replacement Battery Cartridge | RBC53 |
Battery Access | Battery access door |
Battery Replacement Description | Hot-swappable, user replaceable batteries |
Expandable Runtime | No |
VOLTAGE REGULATION | |
Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 81 to 143 |
Overvoltage Correction A feature found in line conditioners and select UPS systems that maintains mains-level power to equipment when prolonged line voltages are lower than normal | Input voltages between 128 and 143V are reduced by 9% |
Undervoltage Correction A feature found in line conditioners and select UPS systems that maintains mains-level power to equipment when prolonged line voltages are lower than normal | Input voltages between 97 and 107V are boosted by 10% |
Severe Undervoltage Correction | Input voltages between 81 and 96V are boosted by 21% |
USER INTERFACE, ALERTS & CONTROLS | |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
Alarm Cancel Operation | |
Audible Alarm | Alarm reports low-battery, fault, overload and replace battery conditions |
LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
SURGE / NOISE SUPPRESSION | |
UPS AC Suppression Joule Rating | 510 |
UPS AC Suppression Response Time | Instantaneous |
EMI / RFI AC Noise Suppression Technology found in select UPS systems that protects against EMI (electromagnetic inerference) and RFI (radio frequency interface) line noise and protects equipment against associated incremental hardware damage, data corruption and audio/video transmission problems | Yes |
SURGE / NOISE SUPPRESSION | |
Output Isolation Transformer A feature found in isolation transformers and select UPS systems where the output power is fully isolated from EMI/RFI line noise, protecting sensitive equipment form potential damage and perfromace problems | Professional grade load isolation transformer |
Surge Voltage Withstand Capability | ANSI/IEEE C62.41 Categories A & B 6KV/200/500 amp 100Khz Ringwave and category B BiWave |
Surge Voltage Attenuation | |
Insertion Loss The loss of signal power resulting from the insertion of a device in a transmission line or optical fiber. Is usually expresed in decibels (dB) | |
PHYSICAL | |
Cooling Method | Fan |
Installation Form Factors Supported with Included Accessories | Tower |
Installation Form Factors Supported with Optional Accessories | Wallmount (UPSWM - tower mounting kit) |
Primary Form Factor | Tower |
Primary UPS Depth (mm) | 234 |
Primary UPS Height (mm) | 325 |
Primary UPS Width (mm) | 191 |
Shipping Dimensions (hwd / in.) | 18.25 x 12.00 x 13.75 |
Shipping Weight (lbs.) | 40.00 |
UPS Housing Material | PVC |
UPS Power Module Dimensions (hwd, in.) | 12.8 x 7.5 x 9.2 |
UPS Power Module Weight (kg) | 16.51 |
UPS Power Module Weight (lbs.) | 36.4 |
ENVIRONMENTAL | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius. |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius. |
Relative Humidity | Up to 95%, non-condensing |
AC Mode Efficiency Rating (100% Load) | >91% |
COMMUNICATIONS | |
Communications Interface | USB |
PowerAlert Software | For local monitoring via the UPS’s built-in USB communications port, download PowerAlert Local software at http://www.tripplite.com/poweralert |
Communications Cable | USB interface cable included |
WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER | |
Transfer Time The time it takes for a UPS to switch from AC on-line mode to DC battery-powered mode. Measured in milliseconds (ms) | 2-4 milliseconds |
Low Voltage Transfer to Battery Power (Setpoint) | 81 |
High Voltage Transfer to Battery Power (Setpoint) | 143 |
SPECIAL FEATURES | |
Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
High Availability UPS Features | Hot swappable batteries |
CERTIFICATIONS | |
UPS Certifications | |
WARRANTY | |
Product Warranty Period (U.S. & Canada) | 2-year limited warranty |
Connected Equipment Insurance (U.S., Canada & Puerto Rico) | $200,000 Ultimate Lifetime Insurance |
Click here to view the manufacturer's item description/brochure
Weight: 37 lb
Warranty: 2 Year Manufacturer
Condition
Brand New
Warranty