TRIPP LITE Part #/MPN: SMART5000XFMRXL
DiscTech Item #: TRI-SMART5000XFMRXL-BN-2Y
- Brand New
- Warranty:2 Year Manufacturer
- Special Order - Ships in 3-5 business days
Interface Types: Serial RS-232 DB9
U Height: 3U
Voltage: 208V
Color: Silver
Tripp Lite SmartPro SMART5000XFMRXL 208V & 120V 5000VA / 3750W Line Interactive Sine Wave UPS 3U Rack Tower - Brand New
Tripp Lite SmartPro SMART5000XFMRXL 208V & 120V 5000VA / 5kVA 3750W / 3.75kW USB / DB9 11 Outlet Line Interactive Sine Wave Uninterruptible Power Supply 3U Rack Tower Extended Run - Brand New
Overview
Tripp Lite 5kVA Smart RM UPS. 5000VA line-interactive UPS for server, network and telecommunications equipment. UPS with internal batteries requires 3 rack spaces installed. Accepts 208V nominal input voltage. Simultaneous 208 & 120V output. Corrects brownouts and overvoltages from 167V to 260V. Sine wave output. Maintains battery-derived AC output during blackouts and severe voltage fluctuations. Expandable runtime with optional external battery packs. 11 output receptacles. NEMA L6-30P input connection with support for user-supplied 50A or hardwire input. Network-grade AC surge and noise suppression. Network management interfaces include USB, DB9 serial and slot for Network Management Card options. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all network interfaces simultaneously. PowerAlert UPS monitoring software is available via free download. Emergency Power Off (EPO) interface. Integrated 8-bank switched PDU. 3-stage metered current monitoring and battery charge LEDs. Utility power and voltage regulation LEDs. Audible alarm. Self-test. 4-post rack mounting accessories included; 2-9USTAND and 2POSTRMKITHD accessories available. Field-replaceable, hot-swappable internal batteries and battery packs.
Features
- 5000VA/3750 watt max. output power capacity compatible with North American 208V/60Hz input voltage
- Supports full output at either 208V or 120V
- 3U rack/tower UPS installs in standard 19 inch rack enclosures with an installed depth of only 25 inches / 63.5cm
- Protects sensitive networking equipment from blackouts, voltage fluctuations and transient surges
- Line Interactive Automatic Voltage Regulation (AVR) corrects 208V nominal input from 167 to 260VAC back to usable 208/120V levels without consuming battery power
- AVR circuits boost undervoltages by 12% and reduce overvoltages by 12%
- Network interfaces support simultaneous communications via USB, DB9 serial and slot for Network Management Card option
- Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLXand SNMPWEBCARD
- USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from www.tripplite.com/poweralert
- Built-in Emergency Power Off (EPO) interface with cable
- Sine wave output in AC and battery mode
- Expandable runtime with optional BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible) external battery packs
- NOTE: BP48V24-2U must either be (1) installed in a recessed position inside the rack so the DC cable can reach the BP connector on the UPS or (2) be installed in a standard front-mount position with a 1 foot 48VDC extension cable BPEXT481
- Half/full load runtime of 20/8.5 minutes with internal batteries
- Intelligent battery management system extends battery life
- Includes 11 output receptacles (2 L6-20, 1 L6-30 & 8 NEMA 5-15/20R)
- Ships with installed L6-30P input plug, supports user supplied 50A replacement plug or hardwire input
- Integrated 8 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual devices
- 3 stage metered LEDs offer current monitoring and battery charge level
- Mains power and voltage regulation LEDs offer at-a-glance power status information
- Front panel switches support self-test and alarm cancel functions
- Included adjustable mounting rails support installation in 4 post 19 inch racks
- UPS ships fully assembled in full compliance with DOT regulations, no time consuming connection of internal batteries by user is required
- Supports upright tower placement with optional 2-9USTAND accessory
Package Includes
- SMART 5000XFMRXL UPS System
- USB & DB9 Serial Cabling
- Mounting hardware for 4-post rackmount installation
- Instruction manual
UPS BATTERY BACKUP | |
---|---|
Model Number | SMART5000XFMRXL |
OUTPUT SPECIFICATIONS | |
Output Volt Amp Capacity (VA) | 5000 |
Output kVA Capacity (kVA) | 5 |
Output Watt Capacity (Watts) | 3750 |
Output kW Capacity (kW) | 3.75 |
Power Factor | 0.75 |
Nominal Output Voltage(s) Supported | 110V 115V 120V 208V |
Nominal Voltage Details | 208/120V nominal output in battery mode |
Frequency Compatibility | 60 Hz |
Output Voltage Regulation (Line Mode) | 208 & 120V (+/- 10%) |
Output Voltage Regulation (Battery Mode) | +/- 5% |
Output Receptacles | (8) 5-15R/20R (2) LG-20R (1) L6-30R |
Load Management Receptacles | Eight switchable single-outlet 5-15/20R load banks |
Output Circuit Breakers | 120A double pole breaker supports L6-20R outlets, 20A branch rated breaker (x2) supports 4 5-15/20R outlets each, L6-30R outlet is unbreakered |
Output AC Waveform (AC Mode) | Sine wave |
Output AC Waveform (Battery Mode) | Pure Sine wave |
INPUT SPECIFICATIONS | |
Rated input current (Maximum Load) | 24A |
Nominal Input Voltage(s) Supported | 208V AC |
UPS Input COnnection Type | L6-30P |
UPS Imput Cord Length (ft.) | 10 |
Recommended Electrical Service | 30A 208V |
Input Phase | Single-Phase |
BATTERY SPECIFICATIONS | |
Full Load Runtime (min.) | 8.5 min. (3750w) |
Half Load Runtime (min.) | 20 min. (1875w) |
Expandable Battery Runtime | Extended runtime supported via optional external battery packs |
External Battery Pack Compatibility | BP48V24-2U(limit 1) BP48V60RT-3U(multi-pack compatible) BP48V27-2US(multi-pack compatible) |
DC System Voltage (VDC) | 48 |
Battery Recharge Rate (Included Batteries) | Less than 4 hours from 10% to 90% (typical, full load discharge) |
Internal UPS Replacement Battery Cartridge | RBC94-3U(quantity 3) |
Battery Access | Front panel battery access door |
Battery Replacement Description | Hot-swappable, user replaceable batteries |
Expandable Runtime | Yes |
VOLTAGE REGULATION SPECIFICATIONS | |
Voltage Regulation Description | Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 167 to 260 |
Overvoltage Correction | Input voltages between 228 and 260 are reduced by 12% |
Undervoltage Correction | Input voltages between 167 and 194 are boosted by 12% |
USER INTERFACE, ALERTS & CONTROLS SPECIFICATIONS | |
Switches | 2 Switches control off/on power status and alarm-cancel/self-test operation |
Alarm Cancel Operation | Power-fail alarm can be silenced using alarm-cancel switch nce silenced, alarm will re-sound to indicate low-battery status |
Audible Alarm | Audible alarm indicates UPS startup, power-failure, low-battery conditions |
LED Indicators | 5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
SURGE / NOISE SUPPRESSION SPECIFICATIONS | |
UPS AC Suppression Joule Rating | 1020 |
UPS AC Suppression Response Time | Instantaneous |
EMI / RFI AC Noise Suppression | Yes |
PHYSICAL SPECIFICATIONS | |
Included Mounting Accessory Description | 4 post 19 inch rackmount |
Installation Form Factors Supported with Optional Accessories | 2 post rackmount(2POSTRMKITHD) Tower(2-9USTAND) |
Primary Form Factor | Rackmount |
UPS Power Module Dimensions (hwd, in.) | 5.2 x 17.5 x 25 |
Rack Height (U Spaces) | 3 |
Minimum Required Rack Depth (inches) | 32 |
UPS Power Module Weight (lbs/kg) | 143.3/65.00 |
Cooling Method | Fan |
UPS Housing Material | Steel |
Minimum Required Rack Depth (mm) | 813 |
Primary UPS Height (mm) | 132 |
Primary UPS Width (mm) | 444 |
Primary UPS Depth (mm) | 635 |
ENVIRONMENTAL SPECIFICATIONS | |
Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius. |
Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius. |
Relative Humidity | 0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) | 366 |
Battery Mode BTU / Hr. (Full Load) | 1423 |
AC Mode Efficiency Rating (100% Load) | 97% |
COMMUNICATIONS SPECIFICATIONS | |
Communications Interface | USB DB9 Serial EPO (emergency power off) Slot for SNMP/Web interface |
Network Management Cards | SNMPWEBCARD TLNETCARD WEBCARDLX |
Network Monitoring Port Description | Supports detailed monitoring of UPS and site power conditions |
PowerAlert Software | For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
Communications Cable | USB and DB9 cabling included |
WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER SPECIFICATIONS | |
Transfer Time | 7 ms (AC to Battery); 1 ms (Battery to AC) typical |
Low Voltage Transfer to Battery Power (Setpoint) | 167 |
High Voltage Transfer to Battery Power (Setpoint) | 260 |
SPECIAL FEATURES SPECIFICATIONS | |
Grounding Lug | Back panel grounding lug |
Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
High Availability UPS Features | Hot swappable batteries |
Green Energy-Saving Features | Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
CERTIFICATION SPECIFICATIONS | |
UPS Certifications | Tested to UL1778 (USA) Tested to CSA (Canada) Tested to NOM (Mexico) Meets FCC Part 15 Category A (EMI) |
Click here to view the manufacturer's item description/brochure
ROHS Compliant
Weight: 59 lb
Warranty: 2 Year Manufacturer
Brand New
2 Year Manufacturer Warranty